Frequently Asked Questions
•What are the typical resistance values for the compressor windings on this model?
Refer to the Whirlpool WRS571CIHZ service manual. Typically, you'll find resistance values between 2-10 ohms between the common and start terminals, and between the common and run terminals.
•How do I test the electronic control board output voltage?
Use a multimeter set to AC voltage. Connect the leads to the compressor terminals on the ECB. Ensure the refrigerator is calling for cooling (e.g., temperature set below current temperature). You should read approximately 120V AC.
•What type of refrigerant does this model use, and what are the EPA regulations for handling it?
The Whirlpool WRS571CIHZ typically uses R600a refrigerant. Technicians must be EPA Section 608 certified to handle and recover refrigerant. It is illegal to vent refrigerant into the atmosphere.