Frequently Asked Questions
•What is the acceptable voltage range for the water inlet valve solenoid?
The water inlet valve solenoid is designed to operate at 120V AC. When energized, it should receive voltage close to this value, depending on your home's electrical supply. A significant drop in voltage (below 110V AC) could indicate a wiring issue or a weak circuit.
•How do I test the flow meter using a multimeter?
To test the flow meter, disconnect the dishwasher power. Disconnect the flow meter's wiring harness. Set your multimeter to measure resistance (Ohms). As you manually rotate the flow meter's internal paddle wheel, the resistance should change (open and close circuit). If the resistance remains constant (either open or shorted), the flow meter is likely defective.
•Where is the water inlet valve located on the Whirlpool WDF520PADM dishwasher?
The water inlet valve is typically located at the lower front or side of the dishwasher, behind the lower access panel. It's where the water supply hose connects to the dishwasher.