Frequently Asked Questions
•How do I access the spark module on my Viking range model?
Access procedures vary. Typically, you need to remove the burner grates, burner caps, and burner bases. The spark module is often located underneath the cooktop surface, requiring its removal (after disconnecting power, of course). Refer to the service manual for detailed instructions for your specific model.
•What is the correct gas pressure for my Viking range if it's converted to propane?
Viking propane ranges typically require 10-12 inches of water column pressure at the manifold. Always verify with the model's service manual and a manometer.
•Where is the flame sensor located on my Viking range burner assembly?
The flame sensor (thermocouple) is typically located near the burner, close to the spark igniter. It's a small metal rod that sits in the flame when the burner is lit.