•What is the typical resistance range for a good RTD sensor at room temperature (70-75°F)?
Typically, a good RTD sensor for a Monogram range will read between 1070 and 1090 ohms at room temperature (70-75°F). Refer to the exact service manual for the specific model.
•How do I test the wiring harness for continuity?
With the power disconnected, use a multimeter set to continuity mode. Place one probe on one end of the wire and the other probe on the other end. A beep or a reading close to 0 ohms indicates good continuity. Check each wire in the harness individually.
•If the RTD sensor tests good, what should I check next?
If the RTD sensor tests good, inspect the wiring harness and connections to the oven control board. If those are okay, the oven control board itself may be faulty and need replacement. Consult a qualified technician for control board diagnosis and replacement.