Frequently Asked Questions
•What is the proper resistance reading for the compressor relay?
The compressor relay should have low resistance (near 0 ohms) when tested for continuity. Infinite resistance indicates an open relay.
•How do I properly discharge the start capacitor before working on the compressor?
Use a 20,000-ohm 2-watt resistor to slowly discharge the capacitor. Connect the resistor leads to the capacitor terminals for several seconds. Verify with a multimeter that the voltage is near 0V before touching the terminals.
•What type of refrigerant is used in the LFXS28968S and what are the proper charging procedures?
The LFXS28968S typically uses R-134a refrigerant. Charging requires a certified technician with EPA Section 608 certification. Refer to the unit's service manual for specific charging procedures and pressures.