Frequently Asked Questions
•What is the typical resistance range for a functioning motor pressure sensor on this model?
Refer to the Hotpoint service manual for the specific model number. However, a general range is often between 5k ohms and 10k ohms at room temperature and zero pressure.
•How do I verify that the wiring harness is not damaged internally without visible signs of damage?
Use a multimeter to perform a continuity test on each wire in the harness. Check for shorts to ground by measuring resistance between each wire and the chassis ground. Flex the harness while testing to identify intermittent breaks.
•If the pressure sensor is receiving the correct voltage, what could cause a false reading at the MCU?
A damaged signal wire between the pressure sensor and the MCU could cause a voltage drop or interference, resulting in a false reading. Also, internal damage to the MCU's analog-to-digital converter (ADC) could misinterpret the signal.