GE Profile Oven Error Code F91: Door Latch Motor Troubleshooting

Solve GE Profile oven F91 error! Our guide helps diagnose & repair a door latch motor stuck halfway. Get your oven working again quickly.

Frequently Asked Questions

How do I access the service mode on my GE Profile oven to run the calibration test?

The procedure for entering service mode varies depending on the specific model. Consult the service manual for your oven or search online for the correct key sequence. Common sequences involve pressing and holding specific buttons simultaneously (e.g., Bake and Broil) for a few seconds.

What voltage should I expect to see at the door latch motor during the self-clean cycle?

You should typically see approximately 120V AC at the door latch motor connector during the self-clean cycle when the MCU is attempting to lock the door. Use a multimeter set to AC voltage to measure this.

How do I test the door lock motor if I suspect it is bad?

First, visually inspect the motor for any signs of damage. Next, check for voltage at the motor connector during a self-clean cycle. If voltage is present but the motor does not operate, the motor is likely faulty. You can also test the motor's resistance with an ohmmeter, comparing it to the specifications in the service manual.