Frequently Asked Questions
•What is the resistance range of the lint filter sensor at room temperature?
The resistance range of the lint filter sensor is typically between 10k and 20k ohms at 70 degrees Fahrenheit. Refer to the service manual for the exact specification for your model.
•Where is the main control board located in the GE Profile UltraFast Combo?
The main control board is typically located behind the control panel, at the top of the appliance. You will need to remove the control panel to access it. Disconnect power before accessing.
•What is the recommended length and bend radius for the exhaust duct?
The recommended maximum length for the exhaust duct is 25 feet, with no more than two 90-degree bends. Each 90-degree bend reduces the maximum duct length by 5 feet. Ensure a minimum bend radius of 5 inches.