•How do I check if the drain pump itself is functioning properly?
After disconnecting power, you can use a multimeter to check continuity across the pump motor terminals. A reading of around 10-20 ohms indicates a good motor winding. You can also carefully apply 120V AC to the pump terminals briefly (with proper safety precautions) to see if the pump runs.
•What is the correct way to vent the drain line to prevent siphoning?
The drain standpipe should be open to atmospheric pressure. Ensure there is an air gap between the end of the drain hose and the standpipe opening. The standpipe should be adequately vented within the building's plumbing system.
•Where can I find a diagram of the drain system for this model?
A detailed drain system diagram is usually included in the service manual, which can be obtained through GE appliance parts suppliers or professional appliance repair resources. You can also find exploded views online by searching the model number and 'parts diagram'.