Frequently Asked Questions
•What is the correct drain hose height for my GE Profile Combo model?
Refer to the installation manual specific to your model number. The height is typically between 30 and 96 inches, but confirming with your manual is essential.
•How do I test the moisture sensor with a multimeter?
First, disconnect the power. Locate the moisture sensor inside the dryer drum. Set your multimeter to the ohms setting. Place the probes on the sensor terminals. Check the reading against the service manual specifications. An open circuit (infinite resistance) or a very low resistance often indicates a faulty sensor.
•Where is the heating element located in my GE Profile Combo?
The heating element is typically located at the rear of the dryer drum, inside a metal housing. Access usually requires removing the back panel of the unit. Always disconnect power before attempting to access the heating element.