GE Café Range Error Code F350: Cooling Fan or Sensor Issue Troubleshooting

GE Café range displaying F350? Learn to troubleshoot a blocked cooling fan or faulty sensor. Get your range working again!

Frequently Asked Questions

What is the expected voltage reading at the cooling fan motor when the oven is in operation?

The cooling fan motor typically operates on 120V AC. Use a multimeter to check the voltage at the motor terminals when the oven is running. If there is no voltage present, the problem may be with the control board or the wiring harness.

How do I properly test the RTD sensor if I don't know the exact room temperature?

Use a meat thermometer to determine the room temperature and use an ohmmeter to test the RTD. Compare this value against the RTD resistance chart. An RTD resistance chart is available in the service manual or from a component supplier online.

If the cooling fan seems to be running, but the F350 error persists, what else could be the issue?

Even if the cooling fan is running, it may not be running at the correct speed. The MCU might be seeing an abnormal RPM from the fan motor (if it is a variable speed fan). Also, a faulty temperature sensor could still be the culprit, as it might be providing inaccurate temperature readings to the control board.