Frequently Asked Questions
•What is the correct gas pressure for this Wolf range model?
The correct gas pressure is typically 10 inches of water column (WC) for natural gas and 11 inches WC for propane. Consult the range's service manual for the specific pressure requirements.
•How do I test the spark module without replacing it?
You can test the spark module by verifying that it receives 120V AC when the burner knob is turned to the 'light' position. Also, check the output voltage using a high-voltage probe. Be extremely careful when working with high voltage. If no output voltage is detected, and the input voltage is present, the module is likely defective.
•Where is the gas shut-off valve located?
The gas shut-off valve is typically located behind the range, either on the wall or floor. It's a small valve with a handle that turns to shut off the gas supply to the range.