•What is the resistance reading of the RTD sensor at room temperature?
This will help determine if the RTD is functioning within its specified range. Consult the service manual for the expected resistance value.
•Is the door lock switch receiving 120V AC when the self-clean cycle is initiated?
This confirms that the control board is sending power to the door lock mechanism as intended.
•Has the oven experienced any recent power outages or surges?