Frequently Asked Questions
•What voltage should I expect to see at the water inlet valve when the washer is trying to fill?
You should see approximately 120V AC at the water inlet valve terminals when the washer is attempting to fill. If you are not seeing voltage, the issue could be with the control board or wiring.
•How do I check the water level sensor?
Disconnect the air hose from the water level sensor. Gently blow into the hose while using a multimeter to check for continuity across the sensor terminals. The continuity should change as you apply pressure. If the sensor doesn't respond, it may be defective.
•Where is the coin trap located, and how do I clean it?
The coin trap is typically located at the bottom front of the washer behind an access panel or near the pump. To clean it, disconnect power and remove the access panel. Carefully unscrew or unclip the coin trap cover and remove any debris. Reinstall the cover and access panel.