Frequently Asked Questions
•How do I test the surface element switch with a multimeter?
Disconnect power to the range. Remove the switch from the control panel. Set your multimeter to the continuity setting. Place the probes on the terminals of the switch. In the off position, there should be no continuity (open circuit). In the on position, there should be continuity (closed circuit).
•Where can I find replacement parts for my Frigidaire range?
You can find replacement parts at appliance parts retailers, both online and in local stores. Be sure to have your range's model number handy to ensure you get the correct parts.
•What is the typical voltage for the igniter circuit?
The igniter circuit typically operates at 120V AC. This voltage is supplied to the spark module when the burner switch is turned on.