Frequently Asked Questions
•What is the typical resistance range for the humidity sensor on this Frigidaire refrigerator model?
The typical resistance range for the humidity sensor is between 5k and 20k ohms at room temperature (70-75 degrees Fahrenheit). Refer to the service manual for the precise specification for your specific model.
•How can I access the service mode on my Frigidaire refrigerator to test the humidity sensor?
The service mode access varies by model. Typically, it involves pressing a specific sequence of buttons on the control panel, such as 'Up-Down-Up-Down' or 'Freezer Temp - Refrigerator Temp - Freezer Temp'. Consult your refrigerator's service manual for the correct sequence.
•If the humidity sensor tests within the correct resistance range, what other components could be causing the E8 error?
If the humidity sensor tests good, the issue may lie with the wiring harness between the sensor and the control board, or a faulty control board itself. Check the wiring for continuity and shorts to ground. If the wiring is good, the control board is likely the issue and may require replacement or professional repair.